diagram | ![]() |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
type | extension of rootType | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
properties |
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
attributes |
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
annotation |
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
source | <xs:complexType name="BlankingSectorType" abstract="false"> <xs:annotation> <xs:appinfo>The Blanking Sector attribute record may be used to convey persistent areas within a scan volume where emitter power for a specific active emitter beam is reduced to an insignificant value. Section 6.2.21.2 </xs:appinfo> </xs:annotation> <xs:complexContent> <xs:extension base="rootType"> <xs:attribute name="recordType" type="xs:unsignedLong"> <xs:annotation> <xs:appinfo>record type</xs:appinfo> </xs:annotation> </xs:attribute> <xs:attribute name="recordLength" type="xs:unsignedShort"> <xs:annotation> <xs:appinfo>The length of the Blanking Sector attribute record in octets.</xs:appinfo> </xs:annotation> </xs:attribute> <xs:attribute name="padding" type="xs:unsignedShort"> <xs:annotation> <xs:appinfo>zero-filled array of padding bits for byte alignment and consistent sizing of PDU data </xs:appinfo> </xs:annotation> </xs:attribute> <xs:attribute name="emitterNumber" type="xs:unsignedByte"> <xs:annotation> <xs:appinfo>indicates the emitter system for which the blanking sector values are applicable</xs:appinfo> </xs:annotation> </xs:attribute> <xs:attribute name="beamNumber" type="xs:unsignedByte"> <xs:annotation> <xs:appinfo>indicates the beam for which the blanking sector values are applicable.</xs:appinfo> </xs:annotation> </xs:attribute> <xs:attribute name="stateIndicator" type="xs:string"> <xs:annotation> <xs:appinfo>indicate if blanking sector data have changed since issuance of the last Blanking Sector attribute record for this beam, if the Blanking Sector attribute record beam has ceased (SISO enumeration EEAttributeStateIndicator uid 300) </xs:appinfo> </xs:annotation> </xs:attribute> <xs:attribute name="padding2" type="xs:unsignedByte"> <xs:annotation> <xs:appinfo>Padding</xs:appinfo> </xs:annotation> </xs:attribute> <xs:attribute name="leftAzimuth" type="xs:float"> <xs:annotation> <xs:appinfo>This field is provided to indicate the left-most azimuth (clockwise in radians) for which emitted power is reduced. This angle is measured in the X-Y plane of the radar's entity coor- dinate system (see 1.4.3). The range of permissible values is 0 to 2PI, with zero pointing in the X- direction. </xs:appinfo> </xs:annotation> </xs:attribute> <xs:attribute name="rightAzimuth" type="xs:float"> <xs:annotation> <xs:appinfo>Indicate the right-most azimuth (clockwise in radians) for which emitted power is reduced. This angle is measured in the X-Y plane of the radar's entity coordinate system (see 1.4.3). The range of permissible values is 0 to 2PI , with zero pointing in the X- direction. </xs:appinfo> </xs:annotation> </xs:attribute> <xs:attribute name="lowerElevation" type="xs:float"> <xs:annotation> <xs:appinfo>This field is provided to indicate the lowest elevation (in radians) for which emit- ted power is reduced. This angle is measured positive upward with respect to the X-Y plane of the radar's entity coordinate system (see 1.4.3). The range of permissible values is -PI/2 to PI/2 </xs:appinfo> </xs:annotation> </xs:attribute> <xs:attribute name="upperElevation" type="xs:float"> <xs:annotation> <xs:appinfo>This field is provided to indicate the highest elevation (in radians) for which emitted power is reduced. This angle is measured positive upward with respect to the X-Y plane of the radar's entitycoordinatesystem(see1.4.3). The range of permissible values is -PI/2 to PI/2 </xs:appinfo> </xs:annotation> </xs:attribute> <xs:attribute name="residualPower" type="xs:float"> <xs:annotation> <xs:appinfo>This field shall specify the residual effective radiated power in the blanking sector in dBm. </xs:appinfo> </xs:annotation> </xs:attribute> <xs:attribute name="padding3" type="xs:unsignedInt"> <xs:annotation> <xs:appinfo>Padding, 32-bits</xs:appinfo> </xs:annotation> </xs:attribute> </xs:extension> </xs:complexContent> <!--abstract='false' base='rootType'--> </xs:complexType> |
type | xs:unsignedLong | ||
annotation |
|
||
source | <xs:attribute name="recordType" type="xs:unsignedLong"> <xs:annotation> <xs:appinfo>record type</xs:appinfo> </xs:annotation> </xs:attribute> |
type | xs:unsignedShort | ||
annotation |
|
||
source | <xs:attribute name="recordLength" type="xs:unsignedShort"> <xs:annotation> <xs:appinfo>The length of the Blanking Sector attribute record in octets.</xs:appinfo> </xs:annotation> </xs:attribute> |
type | xs:unsignedShort | ||
annotation |
|
||
source | <xs:attribute name="padding" type="xs:unsignedShort"> <xs:annotation> <xs:appinfo>zero-filled array of padding bits for byte alignment and consistent sizing of PDU data </xs:appinfo> </xs:annotation> </xs:attribute> |
type | xs:unsignedByte | ||
annotation |
|
||
source | <xs:attribute name="emitterNumber" type="xs:unsignedByte"> <xs:annotation> <xs:appinfo>indicates the emitter system for which the blanking sector values are applicable</xs:appinfo> </xs:annotation> </xs:attribute> |
type | xs:unsignedByte | ||
annotation |
|
||
source | <xs:attribute name="beamNumber" type="xs:unsignedByte"> <xs:annotation> <xs:appinfo>indicates the beam for which the blanking sector values are applicable.</xs:appinfo> </xs:annotation> </xs:attribute> |
type | xs:string | ||
annotation |
|
||
source | <xs:attribute name="stateIndicator" type="xs:string"> <xs:annotation> <xs:appinfo>indicate if blanking sector data have changed since issuance of the last Blanking Sector attribute record for this beam, if the Blanking Sector attribute record beam has ceased (SISO enumeration EEAttributeStateIndicator uid 300) </xs:appinfo> </xs:annotation> </xs:attribute> |
type | xs:unsignedByte | ||
annotation |
|
||
source | <xs:attribute name="padding2" type="xs:unsignedByte"> <xs:annotation> <xs:appinfo>Padding</xs:appinfo> </xs:annotation> </xs:attribute> |
type | xs:float | ||
annotation |
|
||
source | <xs:attribute name="leftAzimuth" type="xs:float"> <xs:annotation> <xs:appinfo>This field is provided to indicate the left-most azimuth (clockwise in radians) for which emitted power is reduced. This angle is measured in the X-Y plane of the radar's entity coor- dinate system (see 1.4.3). The range of permissible values is 0 to 2PI, with zero pointing in the X- direction. </xs:appinfo> </xs:annotation> </xs:attribute> |
type | xs:float | ||
annotation |
|
||
source | <xs:attribute name="rightAzimuth" type="xs:float"> <xs:annotation> <xs:appinfo>Indicate the right-most azimuth (clockwise in radians) for which emitted power is reduced. This angle is measured in the X-Y plane of the radar's entity coordinate system (see 1.4.3). The range of permissible values is 0 to 2PI , with zero pointing in the X- direction. </xs:appinfo> </xs:annotation> </xs:attribute> |
type | xs:float | ||
annotation |
|
||
source | <xs:attribute name="lowerElevation" type="xs:float"> <xs:annotation> <xs:appinfo>This field is provided to indicate the lowest elevation (in radians) for which emit- ted power is reduced. This angle is measured positive upward with respect to the X-Y plane of the radar's entity coordinate system (see 1.4.3). The range of permissible values is -PI/2 to PI/2 </xs:appinfo> </xs:annotation> </xs:attribute> |
type | xs:float | ||
annotation |
|
||
source | <xs:attribute name="upperElevation" type="xs:float"> <xs:annotation> <xs:appinfo>This field is provided to indicate the highest elevation (in radians) for which emitted power is reduced. This angle is measured positive upward with respect to the X-Y plane of the radar's entitycoordinatesystem(see1.4.3). The range of permissible values is -PI/2 to PI/2 </xs:appinfo> </xs:annotation> </xs:attribute> |
type | xs:float | ||
annotation |
|
||
source | <xs:attribute name="residualPower" type="xs:float"> <xs:annotation> <xs:appinfo>This field shall specify the residual effective radiated power in the blanking sector in dBm. </xs:appinfo> </xs:annotation> </xs:attribute> |
type | xs:unsignedInt | ||
annotation |
|
||
source | <xs:attribute name="padding3" type="xs:unsignedInt"> <xs:annotation> <xs:appinfo>Padding, 32-bits</xs:appinfo> </xs:annotation> </xs:attribute> |